Welcome to the official website of Newopto Photoelectric Technology Co., Ltd!

Photodiode manufacturer

It has been established for 14 years,8000+Case witness
National Service Hotline:0755-81459333 / 18028767999
Current location:Home >News >產品資訊 >PIR infrared pyroelectric sensor in the product layout design precautions
PIR infrared pyroelectric sensor in the product layout design precautions

2024-11-13


1. The connection between the PIR and other devices should be as short as possible. On the dual panel or multi-layer board, try not to route the cable below the connection, especially if there is no large current.

2. PIR part of the circuit as far as possible to make a separate PCB board to avoid interference. If it is done on the same board, the circuit of the PIR part should be isolated separately and have separate grounding;

3. The VDD of the PIR is connected to the 100NF capacitor to the ground and is as close as possible to the VDD of the PIR.

4. The bottom of the table is coated with copper, which provides additional shielding protection and noise suppression for the inner signal, reduces the ground impedance and improves the anti-interference ability. However, if the PCB heat is large, the bottom of the PIR tube base should not be covered with copper.
6386710398147222642485279.jpg
5. PIR is recommended to have a separate LDO power supply. PIR signal pin, power supply pins, suggested that series 100 Ω Ω - 1 k resistor.
6386710398176469603928144.png

6. The length of the PIR pin should be as close as possible to the length of 1/2, 1/4, 1/8 of the RF source wavelength.

7. It is recommended that the PIR be at least 3CM away from the radio source.

8. If the installation height of the PIR on the PCB is too high, it is recommended to shield the shell.

9. The diameter of the PIR hole on the PCB is recommended to be about 0.8mm, and the grounding pin is a heat dissipation pad.